Compressive Strength - Harborfoam (2024)

Harbor Foam EPS is a closed-cell, lightweight and resilient, foamed plastic composed of hydrogen and carbon atoms. The mechanical strength of EPS varies with its density. The most important mechanical property of EPS insulation and building products is its resistance to compressive stresses, which increase as the density becomes higher. EPS has a compressive resistance between 10 – 60 psi for most construction applications. Within that range, EPS can be produced to meet specific strength requirements.

ASTM C578, Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation is a consensus-based performance standard that was developed by producers of polystyrene foam, third party testing laboratories, regulatory agencies and building professionals in the North American region. It covers the types, physical properties, and dimensions of cellular polystyrene used as thermal insulation for temperatures from -65 to 165°F. ASTM C578 covers types of EPS thermal insulation currently available and the minimum requirements for the properties considered most important. Flexural strength and compressive resistance values are included. These values were determined based on ASTM C203, Test Method for Breaking Load and Flexural Properties of Block-Type Thermal Insulation and C165, Test Method for Measuring Compressive Properties of Thermal Insulations and/or D1621 for Test Method for Compressive Properties of Rigid Cellular Plastics.

To meet the compressive resistance requirements specified in ASTM C578 polystyrene thermal insulation board must provide the following compressive strengths at 10% deformation when tested in accordance with ASTM D 1621.

Typical Strength Characteristics – EPS Thermal Insulation Board

PropertyUnitsASTM testASTM C 578 Type
IVIIIIIIX
Density rangepcfC3030.901.151.351.80
Flexural StrengthpsiC20325303550
Compressive Resistance –
at yield or 10% deformation
psiC165 or D162110131525

Foundation and Wall Applications

For foundation and wall applications in which the foam insulation bears a minimal load, ASTM C 578 Type I (nominal density of 0.9 pounds per cubic foot) material is adequate. EPS board produced to meet the requirement of Type I EPS has been tested and found to fall within 10 to 14 psi. The resilience of the EPS insulation board provides reasonable absorption of building movement without transferring stress to the interior or exterior finish at the joints.

Roofing

In roofing, Type I EPS material provides the dimensional stability and compressive strength necessary to withstand light roof traffic and equipment weight at reasonably high surface temperatures. EPS foam insulation may experience dimensional and property changes when it is exposed to temperatures greater than 167°F. However, low-density EPS not subjected to load will show no noticeable loss of dimensional stability at temperatures up to 184°F. Duration of temperature, external load conditions, and density are the variables affecting foam insulation at elevated temperatures. EPS should be adequately protected from temperatures greater than 165°F during installation and may require the use of cover boards, reflective ballast, or a light-colored membrane depending upon the roof covering system involved.

Optimum performance of load-carrying insulation is often related to both strength characteristics and resiliency. Resiliency is the ability of a material to recover its strength following deformation caused by stress. If greater strength and rigidity are needed, compressive resistance up to 60 psi is available by increasing the density of the EPS insulation to meet virtually any compressive strength requirement.

Due to its high resiliency and strength characteristics, expanded polystyrene insulation offers:

  • Absorption of the substrate and facing movement caused by temperature changes and structural deflections.
  • Absorption of substrate irregularities.
  • Thickness recovery following excessive construction load exposures.
  • The suitable sub-grade reaction for effective load distribution.

Design Considerations

Compressive and flexural strength values for expanded polystyrene are based on short-term load conditions in accordance with typical ASTM test standards. As do most load-bearing building materials, EPS foam insulation products creep under long-term, continuous load conditions, and, in critical applications, this characteristic must be considered in design calculations. Design professionals should recall that greater strength properties are available from EPS foam by increasing density. Data that reflects deflection resulting from continuous, compressive load exposures for EPS insulation is available.

Exposure of EPS to moisture resulting from such factors as periodic, internal condensation, or moist soil conditions in foundation applications does not affect the mechanical strength characteristics of the EPS thermal insulation board.

Source: EPS Industry Alliance, 2020, www.epsindustry.org/.

Compressive Strength - Harborfoam (2024)

FAQs

What is the compression strength of foam insulation? ›

Sizes and Thermal Properties: FOAMULAR® insulation is available in a variety of thicknesses and standard sizes. Compressive strengths† from 30 psi to 100 psi (210 kPa to 690 kPa) to meet the requirements of nearly every application.

What is the compressive strength of extruded polystyrene foam board? ›

Extruded Polystyrene Board Insulation: ASTM C 578, Type [X, 15 psi minimum compressive strength, 1.30 lb/cu. ft.

How much weight can rigid foam support? ›

To stay at or below 1% deformation – 1lb foam supports 3.5 pounds per square inch. 10ft x 10ft slab of concrete weights 50lbs per square ft X 100 Square feet = 5,000 lbs. 100 square feet of Type I foam can support 50,400 pounds (100*144*3.5 lbs per sqin) at 1% deformation.

What is the compressive strength of Foamular? ›

FOAMULAR® XPS Insulation has compressive strengths of 15, 25, 40, 60 and 100 psi. The variety of products provides different strengths for use in walls, where there is almost no compressive load, or intermediate strength product for use with modest loads such as around foundations, or in low slope roofs.

What does 44lb compression mean? ›

ILD / Compression Rating Explanation

This product has a compression rating of 44 lbs. Compression means the number of pounds necessary to compress the piece of foam by 1 inch in a 7x7 inch area. For example, if you put 44 lbs in a 7x7 inch area, the foam will compress 1 inch. 180 Lbs.

How do you calculate compression foam? ›

The formula for calculating the needed foam concentrate at a flammable liquid release is as follows: Area X Critical Application Rate (CAR) X Eduction Rate (ER) X 15 = Foam Concentrate Needed.

Top Articles
Latest Posts
Article information

Author: Prof. Nancy Dach

Last Updated:

Views: 6459

Rating: 4.7 / 5 (57 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Prof. Nancy Dach

Birthday: 1993-08-23

Address: 569 Waelchi Ports, South Blainebury, LA 11589

Phone: +9958996486049

Job: Sales Manager

Hobby: Web surfing, Scuba diving, Mountaineering, Writing, Sailing, Dance, Blacksmithing

Introduction: My name is Prof. Nancy Dach, I am a lively, joyous, courageous, lovely, tender, charming, open person who loves writing and wants to share my knowledge and understanding with you.